Items |
Technical parameters |
|||
Model |
TPS55M-2000W |
TPS110M-2000W |
TPS160M-2000W |
|
Cable length |
55M |
110M |
160M |
|
Ambient temperature |
-20~45 ℃ (working), -40~65 ℃ (storage) |
|||
Relative humidity |
10-80% RH (working), 5-90% RH (storage) |
|||
Altitude |
≤ 3000m |
|||
Ground |
Input voltage |
190-240Vac wide range input, single-phase 220Vac@45-65Hz |
||
Output power |
3500W (rated long-term output), 3850W (peak value ≤ 30s) |
|||
Storage cable length |
Standard storage cable 55m; 110m and 160m are optional; |
|||
Retraction speed |
0-2m/s, adjustable |
|||
Reel in/out tension |
0-10N, adjustable |
|||
Interface |
Input socket with switch, communication Type-C port, cable output XT60 connector |
|||
Buttons and switches |
High-voltage on/off button, cable forced retraction button, alarm indicator light |
|||
Protection level |
IPx4 |
|||
Size |
360 × 180 × 260 ± 0.5mm, excluding foot pads and handles |
|||
Weight |
9.0 ± 0.2kg, including 55m tethered cable |
|||
Tether cable |
Material |
Silver plated lightweight high-temperature resistant aviation wire, lightweight high-temperature resistant sheath |
||
DC resistance |
10.5 ± 0.2 Ω, 100m@20 ℃ loop |
|||
Tensile strength |
≥ 20kg, resistant to repeated retraction and release times ≥ 500 times |
|||
Insulation strength |
≥ 3000Vdc, no breakdown for 1 minute |
|||
Cable length |
Standard storage cable 55m; 110m and 160m are optional; |
|||
Outer diameter |
2.3 ± 0.1mm |
|||
Weight |
1.0 ± 0.05kg/100m |
|||
Air module |
Input voltage |
580~810Vdc wide range input |
||
Output voltage |
25 ± 0.3Vdc or 50 ± 0.5Vdc, constant voltage output, supporting voltage customization |
|||
Output power |
2000W (rated long-term output), 2500W (peak value ≤ 10s) |
|||
Protection function |
Input overvoltage and undervoltage protection, output overvoltage, overcurrent, short circuit, and over temperature protection |
|||
Isolation voltage |
3000V (Vin-Vout), 1min, leakage current ≤ 5mA, no breakdown, flashover, or corona phenomenon |
|||
Installation method |
Reserved installation ears, fixed with screws |
|||
Heat dissipation method |
External fan active heat dissipation, reserved air duct forced air cooling |
|||
Interface |
Input XT60, output XT60*2 |
|||
Protection level |
IP54 |
|||
Size |
145 × 60 × 42 ± 0.5mm, excluding mounting lugs |
|||
Weight |
510 ± 20g, excluding external connectors |